Sample preparation simplified


Applied Cells - MARS Sample preparation and cell separation

Applied Cells - MARS

Sample preparation simplified

Get high recovery, high purity and high throughput.
The MARS (Multiphysics Automated Reconfigurable Separation) platform is a modular cell processing system with modules that can be customized for various cell separation and purification workflows. Utilizing acoustic force, the Cell Processing Chip (CPC) separates cells based on differences in physical parameters. Specific sub-populations can be isolated in-flow using the matrix-free immuno-magnetic cell separation module. Target cell surface markers are labeled using a biotinylated antibody and isolated using streptavidin conjugated magnetic beads. 
 

  • Ease-of-use and walk-away operation
  • Centrifuge-free wash with higher recovery and lower cell loss
  • White blood cell separation from whole blood in 12 minutes with 98 % viability
  • Negative and Positive selection can be done directly from whole blood
  • Compatible with 5 mL (FACS) tubes, 15 mL tubes and 50 mL tubes
  • Small footprint - dimensions: 52 cm x 40 cm x 51 cm (L x W x H)

Applied Cells

Flow Cytometry Staining Buffer


eBioscience - eBioscience™ Flow Cytometry Staining Buffer

eBioscience - eBioscience™ Flow Cytometry Staining Buffer

Optimize cellular staining for flow cytometry

Quality data requires quality material. Get the best possible result with eBioscience™ Flow Cytometry Staining Buffer.
 

  • Buffered saline solution with bovine serum and sodium azide
  • 0.09 % as preservative
  • Can be used for all steps required in the staining procedure
  • Contains animal serum proteins to help remove non-specific binding of antibodies
eBioscience

Cell Isolation


Falcon® Cell Strainers

Falcon® Cell Strainers

A faster, easier method to isolate single cells

Easy-to-use device for rapidly isolating primary cells and consistently obtain a uniform single-cell suspension.
 

  • Ideal for preparing flow cytometry samples
  • Evenly spaced mesh pores provide consistent and reliable results
  • Extended lip on strainer enables aseptic handling with forceps
  • Fits perfectly into 50 mL Falcon conical tubes
Falcon Corning

Blocking


eBioscience, SouthernBiotech, RayBiotech - Fc Receptor Binding Inhibitor Polyclonal Antibody, Fc Receptor Saturation Reagent, RayBright® Human FcR Block

eBioscience, SouthernBiotech, RayBiotech - Fc Receptor Binding Inhibitor Polyclonal Antibody, Fc Receptor Saturation Reagent, RayBright® Human FcR Block

Reduce non-specific binding

Reduce the risk of false positive signals by blocking the Fc receptors, expressed by a number of cells, prior to primary antibody staining.
 

  • Perform blocking with IgG, either purified or in serum from various species
  • Different sizes available
eBioscience, SouthernBiotech, RayBiotech